Mustang Survival MD3183 LE 151 Life Jacket User Manual


 
CARE AND MAINTENANCE INSTRUCTIONS
Federal Regulations require Coast Guard approved personal flotation
devices (PFDs) that are legibly marked with the Coast Guard approval
number, are in good and serviceable condition, and are the correct size
for each person on board. It is the responsibility of the operator to be
sure this PFD is in serviceable condition. To be considered serviceable,
this PFD shall not exhibit deterioration that could diminish its
performance, such as broken or deformed hardware, detached webbing,
rotted structural components, air leaks or nonfunctional inflators. Unless
worn inflated, this PFD must also be properly armed with a cylinder
installed in the inflator, and single point status indicator showing green.
See Page 3 for instructions. Failure to follow these instructions rigorously
could result in a non-functioning PFD causing injury or death.
Check the following at the intervals listed below.
1) Before Each Use:
i) Examine the single point status indicator through the window
panel, ensuring it is green. If the indicator is red, the mechanism
requires service. See Re-arming Your PFD, p. 8.
ii) Ensure the manual pull-tab is accessible.
iii) Visually examine your Inflatable PFD for damage or excessive
abrasion, wear, tear or contamination. Particular attention must be
paid to the stitching, straps and hardware. If in doubt, send it to your
Mustang dealer for evaluation and/or servicing.
2) Every Two (2) Months:
i) Leak Test: The Inflatable PFD should be tested for general leakage
by orally inflating your Inflatable PFD until firm and let stand 16
hours. A leaking Inflatable PFD will not hold its firmness and should
be replaced. If your Inflatable PFD leaks, take it to your Mustang
dealer for evaluation and/or servicing. Repack the Inflatable PFD as
outlined in the Repacking section (p. 11).
ii) Oral Inflation Valve Test: To check the oral inflation valve, fully
inflate the Inflatable PFD using the oral inflator and hold valve under
water. If bubbles appear, deflate and re-inflate to test again. Should
the leak persist, take your Inflatable PFD to your Mustang dealer for
evaluation and/or servicing.
Inflatable PFD Owner’s Manual 15