Mustang Survival MD3183 LE 151 Life Jacket User Manual


 
CAUTION: To avoid accidental inflation, don't allow the water
to contact the hydrostatic inflator.
iii) Perform a thorough visual examination. See Readiness
Checklist (p. 4).
Perform these tests more often if exposed to potential damage or
used in extreme conditions.
3) After Each Inflation - Re-arm the Inflatable PFD. See Re-arming
Your PFD, p. 8.
4) Annually - Perform the following at the beginning of each boating
season, after inflation, or whenever the integrity of the Inflatable PFD
is in doubt:
i) Check all components for dirt or corrosion. Clean or replace, as
neccessary. See Readiness Checklist (p. 4).
ii) Visually examine your Inflatable PFD for damage or excessive
abrasion, wear, tear or contamination. Particular attention must be
paid to the stitching, straps and hardware. If in doubt, send it to your
Mustang dealer for evaluation and/or servicing.
iii) Perform the Oral Inflation Valve Test: See the Oral Inflation Valve
Test in the Every Two (2) Months Care and Maintenance Instructions
section.
iv) Perform the Leak Test. See the Leak Test in the Every Two (2)
Months Care and Maintenance Instructions section.
v) Ensure the current date is not past the date on the inflator. If it
is, replace the inflator (see Re-arming Your PFD, p. 8).
vi) Ensure the single point status indicator is green (Fig. 1 and 2).
vii) Record as an "Annual" inspection in permanent ink on the Care
and Storage label, in the Date Maintained column.
Repack the Inflatable PFD as outlined in the Repacking section (p. 11).
WARNING: If you are not confident in the self-inspection and
servicing of your Inflatable PFD in accordance with these
instructions, take your Inflatable PFD to a Mustang dealer
for professional servicing or contact Mustang Survival (see
contact information on back of manual).
16 Inflatable PFD Owner’s Manual