Nautique 2008 70141 Boat User Manual


 
8-7
2. Cut and discard the safety wire. (The wire prevents the packing
gland nut from loosening.)
3. Hold the gland nut (large nut) with a pipe wrench and loosen
the locking nut with another pipe wrench.
4. HAND-TIGHTEN the gland nut until the dripping slows down
to about 6-10 drips per minute.
5. Using wrenches as in step 3, re-tighten the locking nut against
the gland nut. Make sure it is VERY TIGHT. If you still
experience leakage, consult your Correct Craft dealer.
6. Loosen one of the hose clamps at the rear of the assembly.
Rotate the assembly until the safety wire eyelet is on top, and
retighten the hose clamps.
CORC109
CORC108
Care and Maintenance
Nautique Ski Sec 8.qxd:Nautique Ski Sec 8.qxd 6/18/07 5:18 AM Page 8-7