Oceanic 04-8791-29 Scuba Diving Equipment User Manual


 
51
OCi OPERATING MANUAL
© 2002 Design, 2013 Doc. No. 12-5335-r01 (6/27/13)
Dives are numbered 1 to 99. Numbering starts at #1 each new calendar day beginning after midnight, or when Reset (by
A+S while viewing the SURF Main).
In the event that a dive’s EDT exceeds 9:59 (min:sec), the data at the 9:59 interval will be recorded for the Log and History
upon surfacing of the unit.
History records information accumulated during the most recent day and adds that information to a full (all time) record.
Battery replacement will not to delete Log or History data.
At any time while in Log or History modes -
M (2 sec) at any time, or 2 minutes of no button action, will revert to the Surface Main screen.
L (< 2 sec) - to toggle the Backlight On/Off.
Will be On for the duration time set.
L (2 sec), while the Backlight is On, - to reset the timer to keep it On for the full duration time set.
DAY (& FULL) LOG DATA 1, information includes (Fig. 120A/B):
> Graphic LOG.
> Day Log >> graphic DIVE - xx OF DAY, dive number (up to 99) for that calendar day, or session of the day if reset.
Full Log >> graphic DIVE - xx OF ALL, dive number (up to 99) of the total number of all dives recorded.
> Time of Day that the dive began (hr:min) with A (or P) icon.
> Day of the week & Date the dive was conducted, that it began.
A (hold) - to scroll through previous dives' Data 1 screens (4/sec), from the one in view toward oldest, repeat after last.
A (< 2 sec) - to step through previous dives' Data 1 screens one at a time.
M (< 2 sec) - to step back through previous dives' Data 1 screens one at a time.
S (< 2 sec) - to access the Data 2 screen for that same dive.
S (2 sec) - to exit and revert to the Log/History Menu.
• M (2 sec), or 2 min of no button action, - to revert to the Surface Main.
• L (< 2 sec) - to toggle the Backlight On/Off.
Will be On for the duration time set.
• L (2 sec), while the Backlight is On, - to reset the timer to keep it On for the full duration time set.
DAY LOG DATA 2 (Full Log Data 2 similar), information includes (Fig. 121):
> Pre dive Surface Interval time (to 59:59 min:sec, then 1:00 to 23:59 hr:min) with SURF icon, dashes ( - : - - ) if Dive # 1.
> Max Depth with graphics FT (or M) and MAX.
> Elapsed Dive Time (up to 9:59 min:sec) with graphic EDT.
> Graphic SEA (or EL2 to EL7), the Altitude level at which the dive was conducted.
> Temperature with ° icon and graphic F (or C), lowest recorded during the dive.
A (hold) - to scroll through previous dives' Data 2 screens (4/sec), from the one in view toward oldest, repeat after last.
A (< 2 sec) - to step through previous dives' Data 2 screens one at a time.
M (< 2 sec) - to step back through previous dives' Data 2 screens one at a time.
S (< 2 sec) - to access the Data 3 screen for that same dive.
S (2 sec) - to exit and revert to the Log/History Menu.
• M (2 sec), or 2 min of no button action, - to revert to the Surface Main.
• L (< 2 sec) - to toggle the Backlight On/Off.
Will be On for the duration time set.
• L (2 sec), while the Backlight is On, - to reset the timer to keep it On for the full duration time set.
DAY LOG DATA 3, PROFILE (Full Log Data 3 similar)
The Log 3 screen allows dives to be analyzed on site without use of the PC interface system, showng Depth as it changes while
EDT is increased or decreased throughout that dive, beginning at descent (0:01 sec).
During dives, Depth and EDT are recorded every 1 second, beginning 1 second after descent to the Dive Start Depth set and
ending upon ascent to < 2 FT (0.6 M) for 1 second.
DAY LOG DATA 3 (Full similar), information includes (Fig. 122):
> Depth with FT (or M) icon ), 0 upon access.
> Graphic DEPTH AT >>.
This means that the Depth shown is at the Time shown.
> Elapsed Dive Time (min:sec) with graphic EDT, 0:00 upon access.
> Graphic PROFILE.
A (hold) - to increase EDT at a rate of 8 seconds EDT for each real time second until released, displaying the Depth values
for each change of the EDT value.
A (< 2 sec) - to increase EDT in increments of 1 second for each press/release, displaying the Depth value for each change
of the EDT value.
M (< 2 sec) - to decrease EDT 1 second for each press/release, displaying the Depth value for each change of the EDT
value.
S (< 2 sec) - to revert to the Data 1 screen for that dive.
S (2 sec) - to exit and revert to the Log/History Menu.
• M (2 sec), or 2 min of no button action, - to exit and revert to the Surface Main.
• L (< 2 sec) - to toggle the Backlight On/Off.
Will be On for the duration time set.
• L (2 sec), while the Backlight is On, - to reset the timer to keep it On for the full duration time set.
Fig. 120A - DAY LOG DATA 1
Fig. 121 - DAY LOG DATA 2
(Full Log Data 2 similar)
Fig. 122 - DAY LOG DATA 3
(Full Log Data 3 similar)
Fig. 120B - FULL LOG DATA 1