Oceanic 04-8791-36 Scuba Diving Equipment User Manual


 
36
OCi OPERATING MANUAL
© 2002 Design, 2013 Doc. No. 12-5335-r01 (6/27/13)
Fig. 83 - DECO STOP ALT 2
Fig. 82 - DECO STOP ALT 1
SAFETY STOP ALT 1 - similar to DEEP STOP ALT 1.
SAFETY STOP ALT 2 & 3 - similar to NO DECO ALT 2 & 3.
--------------------------------------------------------------------------------------------------------------------------------
DECOMPRESSION MODE
Decompression mode activates when theoretical No Decompression time and depth limits are exceeded.
Upon Entry into Deco, the Audible will sound and the LED will flash. The full TLBG and graphic UP with Up Arrow icons will flash
(Fig. 80) until the Audible is silenced by pressing S or 10 seconds elapse.
• S (< 2 sec) - to silence the Audible.
> The TLBG stops flashing when the Audible is silenced.
> The graphic UP with Up Arrow icons continue to flash until within 10 FT (3 M) of and below the required Stop Depth (within
the stop zone), then they are removed.
Managing Deco Stops
To fulfill your decompression obligation, you should make a safe controlled ascent to a depth slightly deeper than, or equal to, the
required Stop Depth indicated and decompress for the Stop Time indicated.
The amount of decompression credit time that you receive is dependent on Depth, with slightly less credit given the deeper you
are below the Stop Depth indicated.
You should stay slightly deeper than the required Stop Depth indicated until the next shallower Stop Depth appears. Then, you
can slowly ascend to, but not shallower than that indicated Stop Depth.
DECO STOP MAIN, information includes (Fig. 81) -
> Current Depth with FT (or M) icon.
> Stop Depth with graphic FT (or M).
> Stop Time (hr:min).
> Graphic GAS - 1 (or 2, 3, 4), the one currently in use.
> NX icon, if any Gas is set for Nitrox.
> Air Time Remaining (up to 99 min) with min and ATR icons, blank if no TMT in use, 99 when => 99.
> Tank Pressure, for the TMT currently in use, with PSI (or BAR) and Link icons; or graphic SPG.
> TLBG with icon.
> VARI with icon, if ascending.
• A (< 2 sec) - to access ALT 1.
• M (2 sec) - to access the Gas/TMT Switch Menu.
• S (< 2 sec) - to acknowledge alarms.
• S (2 sec) - to access the Compass Operating Main.
• L (< 2 sec) - to toggle the Backlight On/Off.
• L (2 sec), while the Backlight is On - to reset the timer and keep it On for the duration time set.
DECO STOP ALT 1, information includes (Fig. 82) -
> Max Depth with FT (or M) and MAX icons.
> Total Ascent Time** (hr:min) with graphic TAT.
> Elapsed Dive Time (hr:min) with graphic EDT.
**TAT includes Stop Times at all required Deco Stops plus vertical Ascent Time based on the max rate allowed.
• A (< 2 sec) - to access ALT 2.
• M (< 2 sec) - to step back to Main.
• Revert to Main in 10 seconds, if A not pressed.
• L (< 2 sec) - to toggle the Backlight On/Off.
• L (2 sec), while the Backlight is On - to reset the timer and keep it On for the duration time set.
DECO STOP ALT 2, information includes (Fig. 83) -
> Time of Day (hr:min_sec), with A (or P) if 12 Hour.
> Temperature with ° icon and graphic F (or C).
• A (< 2 sec) - to access ALT 3.
• M (< 2 sec) - to step back to ALT 1.
• Revert to Main in 10 seconds, if A not pressed.
• L (< 2 sec) - to toggle the Backlight On/Off.
• L (2 sec), while the Backlight is On - to reset the timer and keep it On for the duration time set.
Fig. 81 - DECO STOP MAIN
Fig. 80 - DECO ENTRY
Flashing