OCi OPERATING MANUAL
© 2002 Design, 2013 Doc. No. 12-5335-r01 (6/27/13)
Fig. 71A - NO DECO MAIN
NO DECO MAIN, information includes (Fig. 71A/B) -
> Current Depth with FT (or M) icon
.
> DTR (hr:min) with graphic NDC (or OTR), whichever is less at the time.
> Graphic GAS - 1 (or 2, 3, 4), one in use.
> NX icon, if any Gas is set for Nitrox.
> Air Time Remaining (up to 99 min) with min and ATR icons, blank if no TMT in use, 99 when => 99.
> Tank Pressure, for the TMT currently in use, with PSI (or BAR) and Link (speaker) icons.
If no TMT is in use, the graphic SPG
(meaning Submersible Pressure Gauge) will be displayed with no icons and no ATR.
> TLBG with icon.
> VARI with icon, while ascending.
• A (< 2 sec) - to access ALTs, and the Deep Stop Preview if triggered**.
• M (2 sec) - to access the Gas/TMT Switch Menu**.
• S (< 2 sec) - to acknowledge alarms.
• S (2 sec) - to access the Compass Operating Main**.
• L (< 2 sec) - to toggle the Backlight On/Off.
• L (2 sec), while the Backlight is On - to reset the timer and keep it On for the duration time set.
**These items can only be accessed while viewing the Main.
NO DECO ALT 1, information includes (Fig. 72) -
> Max Depth with FT (or M) and MAX icons.
> Elapsed Dive Time (hr:min) with graphic EDT.
• A (< 2 sec) - to access ALT 2.
• M (< 2 sec) - to step back to the Main.
• Revert to the Main after 10 seconds, if A or M is not pressed.
• L (< 2 sec) - to toggle the Backlight On/Off.
• L (2 sec), while the Backlight is On - to reset the timer and keep it On for the duration time set.
NO DECO ALT 2, information includes (Fig. 73) -
> Time of Day (hr:min_sec), with A (or P) if 12 Hour.
> Temperature with ° icon and graphic F (or C).
• A (< 2 sec) - to access ALT 3, if Nitrox or Deep Stop Preview if Air.
• M (< 2 sec) - to step back to ALT 1.
• Revert to the Main after 10 seconds, if A or M is not pressed.
• L (< 2 sec) - to toggle the Backlight On/Off.
• L (2 sec), while the Backlight is On - to reset the timer and keep it On for the duration time set.
NO DECO ALT 3, information includes (Fig. 74) -
> Current O2 saturation with graphic % O2 SAT.
> Graphic GAS - 1 (or 2, 3, 4), the one currently in use.
> FO2 setting for the Gas in use with icon.
> Current PO2 value (ATA) with icon.
> NX icon.
• A (< 2 sec) - to access Deep Stop Preview if triggered, or the Main if not.
• M (< 2 sec) - to step back to ALT 2.
• Revert to the Main after 10 seconds, if A or M is not pressed.
• L (< 2 sec) - to toggle the Backlight On/Off.
• L (2 sec), while the Backlight is On - to reset the timer and keep it On for the duration time set.
DEEP STOP PREVIEW, information includes (Fig. 75) -
> Graphics DEEP STOP PREV.
> Stop Depth with graphic FT (or M), calculated to be 1/2 Max Depth.
> Stop Time as 2:00 (min:sec).
• A (< 2 sec) - to revert to the Main.
• M (< 2 sec) - to step back to ALT 3.
• Revert to the Main after 10 seconds, if A or M is not pressed.
• L (< 2 sec) - to toggle the Backlight On/Off.
• L (2 sec), while the Backlight is On - to reset the timer and keep it On for the duration time set.
Fig. 72 - NO DECO ALT 1
Fig. 73 - NO DECO ALT 2
Fig. 75 - DEEP STOP
PREVIEW
Fig. 74 - NO DECO ALT 3
Fig. 71B - NO DECO MAIN