Pelco CM9760-KBD-E80 Marine Sanitation System User Manual


 
C1543M-A (7/04) 5
UPGRADING CM9760-KBR FIRMWARE
CAUTION: Only qualified personnel observing electrostatic discharge (ESD) precautions should perform the procedure
below. Always wear a grounding strap connected to an approved grounding source when working on or near exposed
electronic components. Handle circuit boards by their edges.
To upgrade CM9760-KBR firmware to version 8.03, do the following:
1. Using System Manager, upload user-entered keyboard setup information to the System Manager database.
NOTE: This step is necessary to avoid loss of user-programmed keyboard setup information, which is erased when
the KBR is reset later in this procedure. After the KBR is reset, you can download the setup information from
System Manager to the KBR as directed later in this procedure.
2. Log off the KBR.
3. Disconnect the KBR from the 9760 system by unplugging the cable from the COM 1 port on the rear of the KBR (refer to
Figure 4).
4. Remove the KBR from the rack by unscrewing the two Phillips rack-mounting screws from each rack ear on the front of
the KBR (refer to Figure 5).