PYLE Audio PNV2000 Marine Battery User Manual


 
-The
LED
indicators
A.
GREEN:
It indicates the inverter is power on, the cooling fan (PNV2000/PNV3000/PNV4000) is also
activated, and AC power
will
be
delivered
to
the AC outlet.
B.
RED:
It indicates the inverter shutdown caused by low voltage, overload,
or
excessive temperature.
-The
ONIOFF
switch
It enables output AC power at the AC outlet when switched ON. It also acts
as
a manual reset
for
overload,
low
battery voltage
and
overheat fault conditions. Reset occurs by switching
OFF
for 5 seconds after
automatic shout down then back ON again. This manual reset feature prevents unexpected
or
hazardous
restarting of connected AC loads.
-The
AC
outlet
Single and dual AC outlets are provided on
one
end
01
the PNV2000, PNV3000 and PNV4000, make sure
of
the power consumption required before plug in.
When operated from the directly connection to a
12
Volt battery,
any
combination of
115
Volt AC products
with
a total power consumption of
2000
Watts
or
less.
CAUTION:
Do not connect
to
AC DISTRIBUTION WIRING. The inverter is designed
lor
connection directly to
standard electrical and electronic equipment.
Do not connect the inverter to household
or
RV AC distribution wiring.
Do not connect the inverter to any AC load circuit in which the neutral conductor is connected
to
ground
(earth)
or
to the negative
of
DC
(battery) source.
-The
fuse
replacement
If
the inverter is overload and the spade type fuse is blown, open the fuse replacement cover at the rear of
inverter and replace the blown fuse with a new spade type fuse, (25A
X
3/
30A
XI)
lor
PNV2000,
25A
X 6
lor
PNV3000 and (30A X
2/25A
X 6 ) for PNV4000.
Determine the cause
of
the short circuiting before restarting the inverter.
4