MAINTENANCE
Cleaning Instructions
IMPORTANT: Do not use cleaners that contain
ammonia, ethyl acetate, phosphoric acid or
concentrated chlorine bleach. These will cause
damage to the toilet.
Using C.P. (#1PCP22), a bio-enzymatic toilet bowl
cleaner (available from Raritan Engineering), will
keep the bowl clean and fresh smelling.
Recommend Visual Inspection
For leaks at toilet and hose connections
Hose clamps
Condition of hoses
Seacocks
Condition of wires and connections
In-Line Strainer
Cleaning In-Line Strainer
(Sea Water Models only)
1. Shut off intake seacock.
2. Unscrew strainer bowl.
3. Remove filter.
4. Clean bowl and filter with a clean dry cloth.
5. Clean gasket and gasket contact surfaces
thoroughly.
6. Replace gasket, filter and bowl.
7. Open seacock.
8. Check for leaks.
Clean Gasket
and Gasket
Contact Surfaces
Thoroughly
Unscrew
Tighten
Bowl
Filter
MAINTENANCE
3
C.P.