Schumacher PIC-150-USB Marine Battery User Manual


 
• 5 •
The continuous load demand from the equipment or device 3.
being operated exceeds the continuous load rating of the
inverter being used. Solution: use a higher capacity inverter or
lower rated device.
The case temperature becomes hot (exceeds 145°F). 4.
Solution: allow the inverter to cool. Do not block the cooling
slots or air ow over and through the inverter. Reduce the load
on the inverter to the continuous rated output.
RESET: To reset after shutdown occurs, remove the 12-volt plug from
the accessory outlet. Check the source of the problem and correct.
Reinsert the 12-volt plug into the accessory outlet.
IF THE INVERTER FUSE BLOWS7.
Your power inverter is tted with a fuse, which should not have to be
replaced under normal operating conditions. A blown fuse is usually
caused by reverse polarity or a short circuit within the device or
equipment being operated.
If the fuse does blow:
Disconnect the device or equipment immediately.1.
Find the source of the problem, and repair it.2.
Install a new 15-amp fuse. The fuse can be found on the end 3.
of the plug on the inverter.
Do not over-tighten the fuse cap; nger-tight is sufcient.4.
ATTENTION: Do not install a fuse higher than 15-amp, as this may
damage the inverter. Make sure to correct the cause of the blown
fuse before using the inverter again.