Schumacher XI41DU Marine Battery User Manual


 
• 10 •
PROBLEM REASON SOLUTION
Inverter does not
turn on.
Poor contact at
terminals
Fuse is blown.
Inverter may be
defective.
Check for poor
connection to battery
or power supply.
Make sure connection
points are clean. Rock
clamps back and forth
for a better connection.
A blown fuse is
usually caused by
reverse polarity or
a short circuit within
the inverter.
To replace, contact
a qualied service
technician who will
diagnose the inverter
and replace the fuse(s)
with the appropriate
replacement(s).
See warranty and call
Customer Service
1-800-621-5485
(Hours 7:00 am to
5:00 pm CST).
SPECIFICATIONS9.
Model: XI41DU
Maximum Continuous Output .......................................... 410 Watts
Surge Capacity (0.1 second) ........................................... 820 Watts
Optimum Efciency .................................................................. 85%
No Load Current Draw ........................................................... <0.5A
Output Frequency .........................................................60Hz ± 3Hz
Output Wave Form ...........................................Modied Sine Wave
Input Voltage Range........................................... 10.5V – 15.5V DC
Low Battery Alarm ......................................Audible, 11V ± 0.3V DC
Low Voltage Shutdown...............................Under 10.5V ± 0.3V DC
High Voltage Shutdown ................................Over 15.5V ± 0.5V DC