Sterling SSPET 5 Marine Battery User Manual


 
5.1. Main te nance in ter vals
Daily: Check warn ing signs on equip ment for good
leg i bil ity and com plete ness
Wee kly: Check the main ta nan ce unit
Check ope ra ting pres su re of the plant’s supp ly
net work (5-6 bar (72.52-87.02 PSI) sys tem over pres su re)
Month ly: Check functi on of the de vi ce plug
Check the sea lings on the fil ter car trid ges
(ac cor ding to the ac cu mu la ti on of dust)
Ev ery 6 months: Check all elec tri cal and me chan i cal con nec tions
for tight fit
Check the set tings on the le vel pro bes (if pre sent)
Check fil ter con ta mi na ti on, if ne ces sa ry cle an or
re pla ce the fil ter car trid ges
An nually: Re place out let valve seal ing
Ad just valve switch
Af ter 1000
op er at ing hours: Re place car bon brushes
F
The given main te nance in ter vals are av er age val ues.
Check whether in your in di vid ual case the main te nance in -
ter vals must be short ened.
036-4MS
SSPET5
Main te nance 37