9 MEMORY MANAGER MODE
9-3
9.2 Searching Data
This mode is used to search the recorded le data in the DATA COLLECT or LAYOUT mode.
The following 3 search methods in each type of les can be selected.
1: First data search
2: Last data search
3: Point number search(MEAS.DATA, COORD.DATA)
Number search (PCODE LIB.)
MEAS. DATA : Measured data in the data collect mode.
COORD. DATA : Coordinate data for layout, control points and new point data measured in the
layout mode.
PCODE LIB. : The data which was registered with a number from 1 to 50 in Point code library.
Point name (PT#, BS#) , ID, PCODE and Height data (INS.HT, R.HT) can be corrected in the searching
mode.
Measured value can not be corrected.
9.2.1 Measured Data Searching
Example :Point number searching
Operating procedure Operation Display
1 Press the [F3](MEMORY MGR.) key from the
menu 1/3.
[F3]
2 Press the [F2](SEARCH) key.
[F2]
3 Press the [F1](MEAS. DATA) key.
[F1]
4 Press the [F1](INPUT) key and enter File Name.
Press the [F4](ENT) key. *1),2)
[F1]
Enter FN
[F4]
5 Press the [F3](PT# DATA) key.
[F3]
6 Press the [F1](INPUT) key and enter PT#.
Press the [F4](ENT) key. *1)
[F1]
Enter PT#
[F4]
7 Press the [F4](
) key to scroll data for selected
point.
[F4]
*1) Refer to Section 2.6 "How to enter alphanumeric characters".
*2) To show the le list, press the [F2](LIST) key.
"
" represents data shown on the display is the stored data.
Press the [ ]or[ ] key to scroll to next or previous point.
To search MEAS. DATA of the same point number, press[ ]or[ ] key.
MEMORY MGR. 1/3
F1:FILE STATUS
F2:SEARCH
F3:FILE MAINTAN P
SEARCH
F1:MEAS. DATA
F2:COORD. DATA
F3:PCODE LIB.
SELECT A FILE
FN:_________
INPUT LIST ––– ENTER
MEAS. DATA SEARCH
F1:FIRST DATA
F2:LAST DATA
F3:PT# DATA
PT# DATA SEARCH
PT#:_________
INPUT ––– ––– ENTER
PT#
TOP-104 1/2
V
98°36'20"
HR
160°40'20"
TILT
0°00'00"
PT#
TOP-104 2/2
PCODE
R.HT
1.200 m
EDIT