7 DATA COLLECTION
7-7
7.2 Operational Procedure of “DATA COLLECT”
Operating procedure Operation Display
1 Press the [F3](FS/SS) key from the data collect
menu 1/2.
The previous data is shown.
[F3]
2 Press the [F1](INPUT) key and enter PT#.
Press the [F4](ENT) key. *1)
[F1]
Enter PT#
[F4]
3 Enter PCODE, R.HT in the same way. *2),3)
4 Press the [F3](MEAS) key.
5 Collimate the target point.
[F1]
Enter
PCODE
[F4]
[F1]
EnterR.HT
[F4]
[F3]
Collimate
6 Press one of the [F1] to [F3] key. *4)
Example: [F2](SD) key.
Measuring starts.
The measuring data is memorized and the display
changes to the next point. *5)
PT# is automatically incremented.
[F2]
7 Enter the next point data and collimate the next
point.
Collimate
8 Press [F4](ALL) key.
Measuring starts in the same measuring mode of
the previous point.
Data is recorded.
Continue the measuring in the same way.
To nish the mode , press [ESC] key.
[F4]
DATA COLLECT 1/2
F1:OCC.PT# INPUT
F2:BACKSIGHT
F3:FS/SS P
PT#
PCODE :
R.HT : 0.000 m
INPUT SRCH MEAS ALL
PT# =PT-01
PCODE :
R.HT : 0.000 m
1234 5678 90.– [ENT]
PT# :PT-01
PCODE
R.HT : 0.000 m
INPUT SRCH MEAS ALL
PT#
PT-01
PCODE :TOPCON
R.HT : 1.200 m
INPUT SRCH MEAS ALL
VH *SD NEZ P1
V : 90°10'20"
HR: 120°30'40"
SD*[n] < m
> Measuring...
< complete >
PT#
PT-02
PCODE :TOPCON
R.HT : 1.200 m
INPUT SRCH MEAS ALL
V : 90°10'20"
HR: 120°30'40"
SD*[n] < m
> Measuring...
< complete >
PT#
PT-03
PCODE :TOPCON
R.HT : 1.200 m
INPUT SRCH MEAS ALL