3 - 6 Ethernet RMON MultiProbe Module Installation and Operation Guide
Using the Main Configuration Menu
Use the Main configuration menu to:
Display the Modify/View Configuration Values menu
Download new firmware
Initiate a warm or cold start
To display the Main configuration menu:
1. Press the front panel Reset button to re-initialize the module.
2. Hold down the X key within 15 seconds of powering up or resetting
the module.
3. If you miss the 15-second window, press the Reset button to
re-initialize (warm start) the module.
4. When you hold down the X key, diagnostics are terminated and the
following banner is displayed:
Tests interrupted!
Boot System Version x.xx for Ethernet RMON
MultiProbe, Rev x
Built on Thu April x, 17:36:58 EST 199x
Loading configuration system.
Entering configuration system. Please
wait.....