A SERVICE OF

logo

6
ONE YEAR LIMITED WARRANTY
For a period of one (1) year from date of purchase, ATD Tools Inc. will repair or replace, at its option, without
charge, any of its products which fails due to a defect in material or workmanship under normal usage. This limited
warranty is a consumer’s exclusive remedy.
Performance of any obligation under this warranty may be obtained by returning the warranted product, freight
prepaid, to ATD Tools Inc. Warranty Service Department, 160 Enterprise Drive, Wentzville, MO 63385.
Except where such limitations and exclusions are specically prohibited by applicable law, (1) THE CONSUMER’S
SOLE AND EXCLUSIVE REMEDY SHALL BE THE REPAIR OR REPLACEMENT OF DEFECTIVE PRODUCTS AS
DESCRIBED ABOVE. (2) ATD Tools Inc. SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL
DAMAGE OR LOSS WHATSOEVER. (3) ANY IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL BE
LIMITED TO ONE YEAR, OTHERWISE THE REPAIR, REPLACEMENT OR REFUND AS PROVIDED UNDER THIS
EXPRESS LIMITED WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER, AND IS PROVIDED IN
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. (4) ANY MODIFICATION, ALTERATION, ABUSE,
UNAUTHORIZED SERVICE OR ORNAMENTAL DESIGN VOIDS THIS WARRANTY AND IS NOT COVERED BY
THIS WARRANTY.
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply
to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty gives you specic legal rights, and you may also have
other rights which vary from state to state.
TROUBLESHOOTING
Symptom Possible Causes Corrective Action
Crane will not lift load
Release valve not tightly closed
Overload condition
Ensure release valve tightly closed
Remedy overload condition
Crane will lift, but not maintain
pressure
Release valve not tightly closed
Overload condition
Hydraulic unit malfunction
Ensure release valve tightly closed
Remedy overload condition
Contact Atd Tools Tech. Service
Crane will not lower after unloading
Reservoir overlled Ensure load is removed, then drain uid
to proper level
Poor lift performance
Fluid level low
Air trapped in system
Ensure proper uid level
With ram fully retracted, remove oil ller
plug to let pressurized air escape,
then reinstall oil ller plug
Crane will not lift to full extension
Fluid level low
Ensure proper uid level