BMC Software, Inc., Confidential and Proprietary Information
212 Application Enhancement Solutions Messages Manual
BMC74279E AN INPUT/OUTPUT ERROR OCCURRED ON ddname DATA SET.
Explanation: The APPLICATION RESTART CONTROL (AR/CTL) ASAM
Copy utility encountered an unrecoverable I/O error on the given data set (ddname).
System Action: Processing terminates abnormally.
User Response: Check the data control block (DCB) information for the data set.
Check the JES log for any MVS messages that might indicate some type of I/O error.
BMC74283E THERE IS A MISMATCH BETWEEN THE type RECORD MAP AND THE
TRACE RECORD
Explanation: The APPLICATION RESTART CONTROL (AR/CTL) Trace
Format utility detected a mismatch between the given type of trace record map and
the actual trace record in the trace file being processed.
System Action: Processing terminates abnormally.
User Response: Check to ensure that the job is using the correct input trace data
set. Correct the problem, and resubmit the job.
BMC74284E DBD dbdname IS NOT A GSAM DBD
Explanation: APPLICATION RESTART CONTROL (AR/CTL) detected that
the given DBD (dbdname) is not a GSAM DBD.
System Action: The job step terminates abnormally with abend U1553.
User Response: Make sure that the DBD name is correctly spelled. Make sure that
the correct DBD library is specified.
BMC74285E DL/I BATCH REGION PROGRAM SPECIFICATION BLOCK WAS NOT
GENERATED WITH CMPAT=YES OPTION.
Explanation: While executing in a DL/I batch region, APPLICATION
RESTART CONTROL (AR/CTL) detected that the program specification block
(PSB) was not generated with the
CMPAT=YES keyword.
System Action: AR/CTL abnormally terminates the task with abend U1771 and
reason code X’00074285’.
User Response: Regenerate the PSB with the
CMPAT=YES keyword.