![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/0/e3/0e30bc37-ad2c-486b-83c8-58f1fe13bce0/0e30bc37-ad2c-486b-83c8-58f1fe13bce0-bg2b.png)
CY8C24123A
CY8C24223A, CY8C24423A
Document Number: 38-12028 Rev. *I Page 43 of 56
AC Programming Specifications
Table 47 lists the guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V and -40°C
≤ T
A
≤ 85°C, 3.0V to 3.6V and -40°C ≤ T
A
≤ 85°C, or 2.4V to 3.0V and -40°C ≤ T
A
≤ 85°C, respectively. Typical parameters apply to
5V, 3.3V, and 2.7V at 25°C and are for design guidance only.
AC I
2
C Specifications
The following tables list the guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and -40°C ≤ T
A
≤ 85°C, 3.0V to 3.6V and -40°C ≤ T
A
≤ 85°C, or 2.4V to 3.0V and -40°C ≤ T
A
≤ 85°C, respectively. Typical parameters
apply to 5V, 3.3V, and 2.7V at 25°C and are for design guidance only.
Table 46. 2.7V AC External Clock Specifications
Symbol Description Min Typ Max Units
F
OSCEXT
Frequency with CPU Clock divide by 1
a
0.093 –12.3MHz
F
OSCEXT
Frequency with CPU Clock divide by 2 or greater
b
0.186 –12.3MHz
– High Period with CPU Clock divide by 1 41.7 – 5300 ns
– Low Period with CPU Clock divide by 1 41.7
– –ns
– Power Up IMO to Switch 150
– – μs
a. Maximum CPU frequency is 12 MHz at 3.3V. With the CPU clock divider set to 1, the external clock must adhere to the maximum frequency and duty cycle
requirements.
b. If the frequency of the external clock is greater than 12 MHz, the CPU clock divider must be set to 2 or greater. In this case, the CPU clock divider ensures that the
fifty percent duty cycle requirement is met.
Table 47. AC Programming Specifications
Symbol Description Min Typ Max Units Notes
T
RSCLK
Rise Time of SCLK 1 – 20 ns
T
FSCLK
Fall Time of SCLK 1 – 20 ns
T
SSCLK
Data Setup Time to Falling Edge of SCLK 40 – – ns
T
HSCLK
Data Hold Time from Falling Edge of SCLK 40 – – ns
F
SCLK
Frequency of SCLK 0 – 8 MHz
T
ERASEB
Flash Erase Time (Block) – 20 – ms
T
WRITE
Flash Block Write Time – 20 – ms
T
DSCLK
Data Out Delay from Falling Edge of SCLK – – 45 ns Vdd > 3.6
T
DSCLK3
Data Out Delay from Falling Edge of SCLK – – 50 ns 3.0 ≤ Vdd ≤ 3.6
T
DSCLK2
Data Out Delay from Falling Edge of SCLK – – 70 ns 2.4 ≤ Vdd ≤ 3.0
Table 48. AC Characteristics of the I
2
C SDA and SCL Pins for Vdd > 3.0V
Symbol Description
Standard Mode Fast Mode
Units
Min Max Min Max
F
SCLI2C
SCL Clock Frequency 0 100 0 400 kHz
T
HDSTAI2C
Hold Time (repeated) START Condition. After
this period, the first clock pulse is generated.
4.0 –0.6– μs
T
LOWI2C
LOW Period of the SCL Clock 4.7 –1.3– μs
T
HIGHI2C
HIGH Period of the SCL Clock 4.0 –0.6– μs
T
SUSTAI2C
Setup Time for a Repeated START Condition 4.7 –0.6– μs
T
HDDATI2C
Data Hold Time 0 –0– μs
T
SUDATI2C
Data Setup Time 250 –100
a
–ns
[+] Feedback