A SERVICE OF

logo

Design Wash LED Pro™
©Elation Professional, Los Angeles Ca. 26 www.ElationLighting.com
the default setting.
8.4.3 Fans Control - This function is used to change the functionality of the internal
cooling fans. The available selections are: 1) “AUTO” – The fans will automatically
switch between low and high speeds depending on the internal operating temperature. 2)
“HIGH” – The fans will run in high-speed mode regardless of operating temperature. 3)
“LOW” – The fans will remain in low speeds regardless of internal operating
temperature.
8.4.4 Display Setting – The display is designed to turn off during normal operation to
avoid excessive light in situations that require an extremely dark environment. This
function will adjust the time delay the LCD will remain on before it turns off. This function
is disabled as default.
8.4.5 Temperature C/F – This function changes the temperature the unit will display
from either Celsius or Fahrenheit. Celsius is set as default.
8.4.6 Initial effect – This function allows a user to create and assign a custom “Home
Position.” Adjusting the Pan and Tilt values then locking those values into the fixture’s
internal memory creates the new “Home” position. Restoring the fixture’s factory values
can erase this setting.
8.4.7 Wireless DMX
This section will control the functionality of the built-in wireless DMX receiver. See
page 37 for more information on operating this fixture via Wireless DMX.
8.4.8 Restore Default – This function is used to restore the factory settings of the
device. All settings will be set back to the default values (shaded). Any edited scenes will
be lost.
8.5 Reset Functions: The reset function returns a motor to the “Home” position. There are
several reset functions available on this fixture. The list below details the functionality of