Fig. 3 - UEC-8 Control (Inside View)
SENSITIVITY POTENTIOMETER - 92W64
KNOB - 994305
VII. REPLACEMENT PART DATA
1. All replacement parts are keyed on the illustrations which follow. Order replacement parts by part number and part
name, as shown on illustrations. DO NOT ORDER BY PART NUMBER ONLY.
2. Many of the parts on the illustrations, particularly electronic parts, are 'vendor items.' This means that they are
standard commercial parts made by and purchased from other manufacturers. If you order from these outside
sources, use the manufacturer's part number or designated as shown in the Electrical Parts List.
3. Always state the series or serial number of the machine on which the parts are used. The serial number is stamped
on the unit nameplate.
.
AMMETER/INCHES-PER MINUTE METER
(Accy, Refer to Sec. III-A)
VOLTMETER
(Accy, Refer to Sec. III-A)
WSSS, SWITCH -
634518
ISP,
POTENTIOMETER -
995301
IS, SWITCH -
599692
CTS, SWITCH -
672831
SIDE PANEL - 6787866
(OLD PANEL - 2075186)
CABINET - 30782
POWER PILOT LIGHT -
598227
MLS, SWITCH - 97W64
VCP, POTENTIOMETER - 639541
KNOB - 996501
WSP, 10-TURN POTENTIOMETER - 181W85
KNOW - 181W87
NOTE: Two cap screws 5/16" — 18
X 1/2" lg. (provided in cloth bag) for
attaching control to OM-48 Side
Beam Carriage.
COVER - 677867
(OLD COVER - 2075227)
TI, CONTROL
TRANSFORMER
995284
WARNING
ELECTRICAL SHOCK HAZARD
DO NOT OPERATE WITH COVER REMOVED
Fig. 2 - UEC-8 Control, P/N 677190
FN, FILTER
NETWORK - 996918
* WARNING LABEL - 995204
RI, RESISTOR
17240005
* Replace label if it becomes excessively worn or lost.
REVERSIBLE GOV.
BOARD - 675332
LOGIC BOARD - 675330
INCLUDES:
FUSE - 996523 (1/2 A. STD)
TB1, TERMINAL BLOCK -
635568
TOUCH WORK KIT
997868 (OPTIONAL)
INCLUDES:
FUSE - 82W43 (IA. SLO-BLO)