A SERVICE OF

logo

382068-EU-EN-V4.0 12/11
4
ACA
Range Resolution Accuracy Frequency range
Overload
protection
2 to 1000A 0.1A
±
(1.5% + 5)
45Hz to 500Hz 1100A
Crest factor < 3 for stated accuracy
DCV
Range Resolution Accuracy Input impedance
Overload
protection
2 to 600V 0.1V
±
(0.5% + 5) 1M
Ω
600V
ACV
Range Resolution Accuracy
Input
impedance
Frequency
range
Overload
protection
2 to 600V 0.1V
±
(0.5%+5)
1M
Ω
45Hz to 500Hz
600Vrms
Crest factor < 3 for stated accuracy
Peak indication
Range Resolution Accuracy Overload protection
20A~80A 0.1A
±
(10% + 10)
1100A
80A~1000A 0.1A
±
(6% + 10)
1100A
Peak detect acquisition time .1ms
Peak indication
Range Resolution Accuracy Overload protection
20V~80V 0.1V
±
(10% + 10)
600Vrms
80V~600V 0.1V
±
(6% + 10)
600Vrms
Peak detect acquisition time .1ms
Audible continuity
Range
Continuity
beeper
Open circuit voltage
Overload
protection
< 50
Ω
3.2V 600Vrms
Resistance (
Ω
)
Range Resolution Accuracy
Open circuit
voltage
Overload
protection
10K
Ω
1
Ω
±
(1% + 5)
3.2 V 600Vrms
Diode test
Range Resolution Overload protection
0.001V 600Vrms
Frequency (Hz)
Range Resolution Accuracy
Voltage
sensitivity
Overload
protection
1KHz 0.1Hz
5KHz 10 Hz
±
(0.5% + 5)
10V or 10A 600V / 1100A