<3>TONE DETECTION - this WAVELENGTH OPTION is used to associate five
tone detection frequencies with five calibrated wavelengths, as well as set the
FiberMeter into AUTO WAVELENGTH detection mode.
The screen at right shows pre-configured tone options.
TONE - moves the tone selection highlight to the next tone.
WAVE - toggles the wavelength of the currently selected tone.
AUTO - toggles the AUTO WAVELENGTH detection feature ON or OFF.
<4>LCD CONTRAST - this option allows the user to set the contrast of the liquid
crystal display (LCD).
DOWN - lightens the screen in case it is too dark
UP - darkens the screen in case it is too light
Press to return to the METER CONFIG MENU.
Setting Tone Detection Options
1-7
FEATURES & FUNCTIONS
UNIT 1
<5>PORT DIAGNOSTICS - this option performs diagnostic tests on the RS-232
serial port, and also the optical ports, if the optional light source is installed.
NOTE: <2>OPTICAL DATA PORT WILL ONLY APPEAR ON THE SCREEN ON
MODEL FO602
Port Diagnostics
Setting LCD Contrast
Set Toning Options
NOTE: shown above is the
default tone configuration
TONE
AUTO
600Hz
1000Hz
1500Hz
2000Hz
300Hz
_____________________
WAVELENGTH: OFF
WAVE AUTO
1310nm
1300nm
1490nm
1550nm
850nm
Set LCD Contrast
XXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXX
DOWN
XXXXXXXXXXXXXXXXXXXXX
CONTRAST
XXXXXXXXXXXXXXXXXXXXX
_____________________
UP
PORT
DIAGNOSTICS