6. Connect the desired drain plumbing to the 1¼–inch drain valve.
7. Test the cooker electrical system:
a. Plug the cooker electrical cord into a grounded electrical receptacle of appropriate voltage.
(Check the rating plate on the cooker door to determine the proper voltage).
b. Place the power switch in the ON position and verify that the display indicates – LO.
c. Place the cooker power switch in the OFF position. Verify that the display is blank.
8. Refer to the rating plate on the inside of the cooker door to verify that the cooker is configured
for the types of gas being supplied before connecting the quick-disconnect device or piping from
the gas supply line.
9. Refer to the table below to verify the minimum and maximum gas supply pressures for the type of
gas being used.
Gas
Normal (Pn)
(mbar)
(1)
Minimum (Pmin)
(mbar)
(1)
Maximum (Pmax)
(mbar)
(1)
G20 20 17 25
G25 20 or 25 20 30
G31 30 or 37 25 35 or 45
G31 50 42,5 57,5
CE Standard
for Incoming Gas Pressures
(1) mbar = 10,2mm H
2
O
References for CE Standard are Tables 6 and A.2 of EN 203-1:1993
Gas Minimum Maximum
Natural
6.0" WC
1.62 kPa
16.19 mbar
14" WC
3.48 kPa
34.87 mbar
Propane
11" WC
2.74 kPa
27.37 mbar
14" WC
3.48 kPa
34.87 mbar
Non-CE Standard
for Incoming Gas Pressures