G0572 Hanging Air Filter with Remote
-7-
Figure 1. Typical type 5-15 plug and receptacle.
Serious personal injury could occur if you
connect the machine to the power source
before you have completed the set up pro
-
cess. DO NOT connect the machine to the
power source until instructed to do so.
110V Operation
Amperage Draw
The
1
⁄5 HP motor on the Model G0572 will draw
the following amps on the highest setting:
Motor Load ..............................................
3 Amps
Circuit Breaker Requirements
Make sure the supply circuit, circuit breaker, or
fuse can carry the additional 3 amp load since
other machines may be using the same circuit. If
the total amperage load of all machines and the
air filter unit exceeds the amperage rating of the
circuit breaker or fuse, use a different circuit that
can carry the load.
DO NOT modify an existing low-amperage circuit
by only replacing the circuit breaker with a
breaker rated for a higher amperage. The breaker
and the complete circuit must be replaced by a
qualified electrician.
Circuit Breaker .........................................10 Amp
SECTION 2: CIRCUIT REQUIREMENTS
Plug Type
The Model G0572 is supplied with a 5-15 plug,
similar to Figure
1.