6. HOUSING FINAL STEP
• Center housing so tunnels are even on both sides.
• Mount rear housing adapter plate. This piece is 10” long and the width of the housing.
• Drill and mount plate to housing using ¼ x ¾” Stainless Carriage bolts and serrated nuts.
Note: Carriage bolt head must be on floor side of housing.
Note: Be sure to check under vehicle for obstructions.
***The (1) far passenger side hole is located
overtop of refrigerant lines. Be sure to not
attach the extension plate in these locations due
to these refrigerant lines.***
• Extension plate is already attached at this
time. Attach rear housing extension plate to
vehicle using ¼” x 1” hex head lag bolts. Pre-
drill w/ 3/16” pilot. Do not attach the bolt
located above the refrigerant line.
• Tighten all loose bolts on tunnels and legs.
7. DOOR PANELS AND WINDOW GUARDS:
• Center door panel’s mark and pre-drill holes to 5/32”.
• Attach to doors using #10 x ¾” Stainless Sheet Metal Screws
• Center hinging window guard on door panel and mount using #10 x ½” Stainless Sheet
Metal Screws. A 5/32” pilot hole is necessary.
• Remove weather stripping from area where window guard bracket will attach.
• With top mounting bracket for hinging window guard attached, hinge window up and
mark placement for top mounting bracket.
Note: It may be necessary to contour the window guard to the match the contour of the OEM door.
• Hinge down and remove top mounting bracket from guard.
• Mount to location marked previously using #10 x ½” Stainless sheet metal screws.
• Make sure that holes in window guard align with holes in mounting bracket.
• Re-attach weather stripping to door.
Top Mounting
Bracket
Refrigerant