HP 750W Power Supply
Part Number - AC 750W PSU
512327-B21 Option Kit
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal) (Hz)
50/60
Nominal Input Voltage (Vrms)
100 120 200 208 220 230 240
Max Rated Output Wattage Rating
750 750 750 750 750 750 750
Nominal Input Current (A rms)
8.9 7.4 4.3 4.1 3.9 3.7 3.6
Max Rated Input Wattage Rating
(Watts)
857 847 824 825 820 820 820
Max. Rated VA (Volt-Amp)
894 884 859 859 854 854 854
Efficiency (%) at Max. Rated Output
Wattage
87.5 88.5 91 91 91.5 91.5 91.5
Power Factor
0.97 0.97 0.97 0.97 0.97 0.97 0.97
Leakage Current (mA)
0.42 0.50 0.83 0.87 0.92 0.96 1.00
Max. Inrush Current (A peak)
30 30 30 30 30 30 30
Max. Inrush Current duration (mS)
20 20 20 20 20 20 20
Maximum British Thermal Unit
Rating (BTU-Hr)
2925 2892 2812 2812 2797 2797 2797
HP 500W Power Supply
Part Number - AC 500W PSU
515915-B21 Option Kit
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal) (Hz)
47/63
Nominal Input Voltage (Vrms)
100 120 200 220 230 240
Maximum Rated Output Wattage
500 500 500 500 500 500
Nominal Input Current (A rms)
5.74 4.99 2.86 2.58 2.46 2.36
Max Rated Input Wattage Rating
(Watts)
568 568 562 556 556 556
Max. Rated VA (Volt-Amp)
574 574 573 567 567 567
Efficiency (%) at Max. Rated Output
Wattage
88 88 89 90 90 90
Power Factor
0.99 0.99 0.98 0.98 0.98 0.98
Leakage Current (mA)
0.42 0.50 0.81 0.91 0.95 1.00
Max. Inrush Current (A peak)
30 30 30 30 30 30
Max. Inrush Current duration (mS)
20 20 20 20 20 20
Maximum British Thermal Unit
Rating (BTU-Hr)
QuickSpecs
HP ProLiant DL160 Generation 6
Power Specifications
DA - 13247 Worldwide QuickSpecs — Version 11 — 11.16.2009