A SERVICE OF

logo

Power
ProLiant DL160 G6 Fully Configured
115V/60Hz 220V/50Hz
Fully Loaded System Input Wattage
(W)
448 445
Fully Loaded System Input Current
(A rms)
3.833 2.046
Fully Loaded System Thermal
(BTU- Hr)
1529 1518
Fully Loaded System VA
(Volt-Amp)
449 454
System Inrush Current with all power supplies loaded
(A)
10.1 10.96
Power cord requirements
Nema 5-15P to IEC320-C13
IEC320-C13 to IEC320-C14
NOTE:
Power shown is for a fully configured system consisting of (2) CPU, (8) double-sided DIMMs, (2) HDDs, (1) CD-ROM, and (2)
PCI cards.
Power Cord
AF556A
Server Power Cords
One 6' Highline (IEC-IEC) power cord ships standard
NOTE:
HP ProLiant DL servers no longer ship standard with NEMA power cords (163719-002) that
allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily connected
to PDU's in data center racks so they now ship standard with only a PDU power cord (416151-B21). If a
user wishes to power a ProLiant DL server using a 110V receptacle (NEMA-15), the NEMA power cord
(227099-001) must be ordered separately.
If customers require a local power cord, they can check the power cord matrix for the appropriate cord.
Please see the following power cord matrix:
http://www.hp.com/go/powercordmatrix
.
QuickSpecs
HP ProLiant DL160 Generation 6
System Specifications
DA - 13247 Worldwide QuickSpecs — Version 11 — 11.16.2009
Page 46