A SERVICE OF

logo

48 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide
Removing a hard drive blank
CAUTION: To prevent improper cooling and thermal damage,
do not operate the server unless all bays are populated with either a
component or a blank.
SAS and SATA hard drive guidelines
When adding SAS hard drives to the server, observe the following general
guidelines:
The server supports four SAS or SATA hot-plug hard drives.
The system automatically sets all drive numbers.
If only one hard drive is used, install it in the bay with the lowest number.
Hard drives must be SFF types.
Drives must be the same capacity to provide the greatest storage space
efficiency when drives are grouped together into the same drive array.
NOTE: ACU does not support mixing SAS and SATA drives in the
same logical volume.
For additional requirements, refer to the storage solution documentation.