Page 13 of 15 Rev: 1/21/2014 7:29 AM
Supported (by setting local on-level to zero)
X10 minimum transmit level
X10 minimum receive level
Mounting
Mounts in single or multiple-ganged junction box. Control 200W less load for
each immediately adjacent SwitchLinc Dimmer installed. For example, 600 W
load control becomes 400 W with another dimmer to the immediate right or left.
Use a triple-gang box with a mechanical switch in the center to avoid de-rating.
Wires
Switch paddle and frame color
UV stabilized polycarbonate
Optional (off by default)
1 dual-color red/green and 9 white
Operating temperature range
32
to 104
F (0
to 40
C)
Storage temperature range
-4
to 158
F (-20
to 70
C)
120VAC (+/- 10%), 60 Hz, single phase
Neutral connection required
Wired-in incandescent lighting fixtures
Maximum load 1000 watts (uses 12 Amp triac dimmer)
Retains all settings without power
Yes, saved in non-volatile EEPROM
Standby power consumption
ETL (Intertek Testing Services) to UL/ANSI standard
Troubleshooting
SwitchLinc’s LEDs and connected load
will not turn on
SwitchLinc is not getting power
Make sure the circuit breaker is turned
on
Check the light fixture to ensure all
connections are tight and no bare wires