Replace belt whenever a burning
rubber smell caused by excessive
slippage occurs.
➢➢
Remove lower plate. See “Removing
and Installing Lower Plate”
➢➢
Remove agitator by carefully lifting
out.
➢➢
Remove worn or broken belt.
➢➢
Clean agitator and the end caps.
➢➢
Loop new belt around motor shaft
and agitator belt groove; see
illustration for correct belt routing.
➢➢
Reinstall agitator back into nozzle
housing grooves.
➢➢
After reinstalling the agitator, turn it
by hand to make sure that belt is not
twisted or pinched and that all
rotating parts turn freely.
➢➢
Reinstall lower plate. Ensure tabs are
locked into slots.