Camera selection and alarm operations are made on the
front panel of the unit or WV-CU360C System Controller.
Camera Selection
Front Panel Operation
You need to remove the front cover loosening the screw
with a screw driver before starting operation.
Press a camera number button.
The selected camera picture is displayed on the moni-
tor connected to the SPOT OUT terminal on the rear of
the unit.
WV-CU360C Operation
Enter a camera number with numeric buttons, then
press the CAM/SET button.
The selected camera picture is displayed on the monitor
connected to the SPOT OUT terminal on the rear of the unit.
Alarm Operation
Alarm Input
An alarm arises in the following cases.
Terminal alarm
A sensor input is supplied to the unit telling that a
change has been detected.
Site alarm
A camera detects motion change in video (VMD, Video
Motion Detection).
Processing
The spot image changes to that of the alarm activated
camera when ALARM MODE is set to ON in the setup.
The camera moves to the preset position.
“ALARM ***” blinks overlaid on the spot image when
ALARM DISPLAY is set to ON.
The alarm indicator blinks.
Alarm Output
The alarm activation is informed to the connected peripher-
als via the DATA terminal or ALARM/REMOTE terminal
when the terminal is set to the alarm output mode. Output
duration is specified with the ALARM OUTPUT setup.
Digital Disk Recorder enters a specific recording mode.
Video Multiplexer changes pick-up frame rate and
frame order.
• System Controller makes the alarm indicator blink on
the controller.
OPERATION
1234
CAM
SET
ALARM 001