28
Camera selection and alarm operations are made on the
front panel of the unit or WV-CU360C System Controller.
■ Camera Selection
● Front Panel Operation
• You need to remove the front cover loosening the screw
with a screw driver before starting operation.
• Press a camera number button.
The selected camera picture is displayed on the moni-
tor connected to the SPOT OUT terminal on the rear of
the unit.
● WV-CU360C Operation
• Enter a camera number with numeric buttons, then
press the CAM/SET button.
The selected camera picture is displayed on the monitor
connected to the SPOT OUT terminal on the rear of the unit.
■ Alarm Operation
● Alarm Input
An alarm arises in the following cases.
• Terminal alarm
A sensor input is supplied to the unit telling that a
change has been detected.
• Site alarm
A camera detects motion change in video (VMD, Video
Motion Detection).
● Processing
• The spot image changes to that of the alarm activated
camera when ALARM MODE is set to ON in the setup.
• The camera moves to the preset position.
• “ALARM ***” blinks overlaid on the spot image when
ALARM DISPLAY is set to ON.
• The alarm indicator blinks.
● Alarm Output
The alarm activation is informed to the connected peripher-
als via the DATA terminal or ALARM/REMOTE terminal
when the terminal is set to the alarm output mode. Output
duration is specified with the ALARM OUTPUT setup.
• Digital Disk Recorder enters a specific recording mode.
• Video Multiplexer changes pick-up frame rate and
frame order.
• System Controller makes the alarm indicator blink on
the controller.
OPERATION