Section 7: Replacement Procedures
SATO M10e Service Manual PN 9001113A Page 7-27
8 Install the left, front, and top housing covers.
9 Restore power and test cycle to ensure proper function.
Figure 7-20, Cutter Sensor Replacement
EEPROM CHIP REPLACEMENT
The EEPROM chip (1) is connected on the main circuit board (2). It may be replaced by
removing the left housing cover to access the main circuit board and manually disconnecting
chip (1). The replacement chip (1) is inserted into the same connector in the same orientation as
the one removed. Perform Factory Reset procedures following component replacement.
NOTE: Figure 10-1 of the Diagrams & Schematics section provides guidance
on housing cover installation.
NOTE: Figure 10-1 of the Diagrams & Schematics section provides guidance
on housing cover removal and installation.
NOTE: Figure A properly oriented chip will be applied with its notched end
facing toward the left.