OPERATION INSTRUCTION continued
Multi_Ch_Rec: "On, Off" are the 2 different status settings available. Use the cursor to select
and press [Enter] to confirm this function. While "On" is selected, there will be 4 multiple
channels interface display as shown below:
• Horizontal Row: Channel "1~8" (for 4 channels device only 4 available)
• Vertical Column: Alarm Channel "1~8" (for 4 channels device only 4 available)
• "*" : Press [Enter] to select and cancel this;
• Example: As seen from above, for the row 1, while alarm channel 1 received signal,
the channel 1 and 2 start recording, channel 3 and 4 not taking any action.
• Example: For the row 2, while alarm channel 2 received signal, only channel 2 start
recording, other channels not taking any action.
Multi_Ch_Output: "On, Off" 2 difference status setting. Using the cursor to select and press
[Enter] to confirm this function. While "On" selected, there will be 4 multiple channels inter-
face display as shown above.
A-6 Channel Setting:
Highlight and select Channels, then press [Enter]for this selection, the sub-menu will shown
(as below), then select the required area.
• Title: Channel name. Use the cursor to select and press [Enter] to key-in the name
and re-press [Enter] to confirm this function.
• Cover: "On, Off" 2 difference status setting. Using the cursor to select and press [Enter]
to confirm this function. While "On" selected, there will be cover display setting as
shown below:
Alarm Record Settings
Ch Alarm In_Mode
1 On Close Alarm_Delay: 005s
2 Off Open Out_Delay: 005s
3 On Open Keep_Delay: 005s
4 Off Open Multi_Ch_Rec: On
Multi_Ch_Output: On
Return