3M WSMONITOR 2 Marine Instruments User Manual


 
9
Operation
Place a wrist band on your wrist and plug the coiled cord banana plug into
the monitor’s banana jack. The monitor will display a green light when a
functional wrist strap with good skin contact is connected to the unit.
The unit will sound an alarm and display a red light if the wrist strap becomes
defective or if the person is not in contact with the band.
Unplug the wrist strap coiled cord from the unit to stop the alarm.
Monitor will alarm if the continuity from the monitor to the mat to ground is
lost.
Calibration / Verification
Adjustments or calibration are not required for the 3M
Constant Monitors
WSMONITOR1, WSMONITOR2, WSMONITOR3. The TMTOOL unit
simulates a correctly functional person and wrist strap (Accept) and an open
circuit (Reject). The TMTOOL also simulates high resistance for verification of
your work surface.