ACR Electronics RLB-38 Marine GPS System User Manual


 
Y1-03-0250 Rev. B 23
To remove the expired HRU
When opening the SeaShelter
3
™ lid, note that the beacon is installed with
the lanyard face in. Pull the beacon with steady pressure from the bracket.
Do not get beacon wet while out of bracket. The HRU has a keying feature
that locks it to the bracket. If you view the HRU rod as the center of a clock,
a properly installed HRU will rest at the 7 o’clock position, as shown in the
picture above.
WARNING:
The HRU holds down an ejection spring. The spring must
be held in place during the removal and installation of the HydroFix™ to
prevent injury.
Depress the top of the ejection spring. This will relieve pressure on the HRU
and allow it to be rotated counterclockwise to the 5 o’clock position. The
HRU is now free to be removed. Slowly relieve pressure from the ejection
spring and allow it to deploy.
WARNING:
Discard the expired HRU. Failure to replace the entire
assembly may cause the bracket to malfunction.
WARNING:
Be sure to use only ACR’s HydroFix™ HRU (ACR P/N
9490) in the SeaShelter
3
™. Use of unauthorized replacement parts will void
your warranty and may cause the bracket to malfunction.
Check the date of manufacture on the new HRU. Follow the instructions that
accompany the HydroFix™ for marking the next expiry date and for
selecting the correct rod adapter for the SeaShelter
3
™.
To install the new HRU
Apply pressure to the ejection spring and hold it flat against the bracket.
With your free hand place the new HRU into the key way in the 5 o’clock
position and rotate clockwise to the 7 o’clock position. Slowly remove
pressure from the ejection spring. The HRU should now be held in the 7
o’clock position with the pressure on the ejection spring.
Reinstall the beacon with lanyard face in. Beacon should fit snugly in the
bracket with the antenna captured by the bracket. Reinstall the lid by seating
the bottom of the lid to the detent on the base. Close the upper portion of
the lid so the HRU rod lines up with the spring loaded knob. With gentle
pressure, hold the lid while you turn the lock counterclockwise until it stops,
then clockwise until it stops. This should capture the HRU and snap the lid
into a locked position. Confirm that the lid is attached to the bottom of the
bracket and the HRU.
NOTE:
Whenever a beacon is returned for service, it
must be accompanied by the bracket.