Campbell Hausfeld CS115 Marine Instruments User Manual


 
CS115 Barometric Pressure Sensor
9
;Turn off CS115
;
4: Do (P86)
1: 58* Set Port 8* Low
5: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
6: Real Time (P77)
1: 0110 Day,Hour/Minute (midnight = 0000)
7: Sample (P70)
1: 1 Reps
2: 1* Loc [ P_mb ]
*Table 2 Program
02: 0.0000 Execution Interval (seconds)
*Table 3 Subroutines
End Program
-Input Locations-
1 P_mb
* Proper entries will vary with program and datalogger channel, and input location assignments.
5.1.3 Period Averaging Measurement Example for CR23X
EXAMPLE 3. Sample Program for CR23X
;{CR23X}
;
*Table 1 Program
01: 1 Execution Interval (seconds)
;Turn on CS115 one minute before the hour
;
1: If time is (P92)
1: 59 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 41* Set Port 1* High
;Measure CS115 at the top of the hour
;
2: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 30 Then Do