showhardconf(8)
328 SPARC Enterprise Mx000 Servers XSCF Reference Manual • Last Revised November 2007
EXTENDED
DESCRIPTION
When the configuration and status information regarding FRUs and domain
information are displayed, for any failed or degraded unit, an asterisk (*)
indicating an abnormal unit is displayed along with any of the following states:
EXAMPLES
EXAMPLE 1 Displays the information of the FRUs in SPARC Enterprise M5000.
Status Description
Faulted The component is faulty and is not operating
Degraded The component is operating. However, either an error has been
detected or the component is faulty. As a result, the component
might be operating with reduced functionality or performance.
Deconfigured As a result of another component's faulted or degraded status,
the component is not operating. (The component itself is not
faulted or degraded.)
Maintenance The component is under maintenance. A deletefru(8),
replacefru(8), or addfru(8) operation is currently underway
Normal It is operating normally.
XSCF> showhardconf
SPARC Enterprise M5000;
+ Serial:BE80601021; Operator_Panel_Switch:Service;
+ Power_Supply_System:Single; SCF-ID:XSCF#0;
+ System_Power:On; System_Phase:Cabinet Power On;
Domain#0 Domain_Status:Powered Off;
MBU_B Status:Normal; Ver:0101h; Serial:7867000297 ;
+ FRU-Part-Number:CA20393-B50X A2 ;
+ Memory_Size:64 GB;
CPUM#0-CHIP#0 Status:Normal; Ver:0201h; Serial:PP0629L068 ;
+ FRU-Part-Number:CA06761-D104 A0 ;
+ Freq:2.150 GHz; Type:16;
+ Core:2; Strand:2;
CPUM#0-CHIP#1 Status:Normal; Ver:0201h; Serial:PP0629L068 ;
+ FRU-Part-Number:CA06761-D104 A0 ;
+ Freq:2.150 GHz; Type:16;
+ Core:2; Strand:2;