After loading all charts desired, the chart
conversion (from ENC to SENC) automatically
starts.
8. At this time, the message [No Base Cell
available] and chart cell numbers are displayed
in the [S57 LOAD] window. Then, place the
cursor on the [OK] button and press the
[SELECT] key.
The chart CD-ROM contains all chart data, but
there are some areas which the base charts cell
(last three digits of chart number : 000) are not
installed in the ECDIS. These chart cell numbers
are displayed.
9. If the message [Update number is too low] and
chart cell numbers are displayed in the [S57
LOAD] window, place the cursor on the [OK]
button and press the [SELECT] key
This message means that the ECDIS does not
update older version charts contained in the
CD-ROM.
For example, if the lower three digits of the chart
numbers are 001 to 028, 001 - 015 are not
updated (not used) and 016 - 028 are updated.
The chart cell numbers to be updated are displayed
in the [Conversion list] on the [SENC CONVERT]
window. The chart is updated cell by cell from the
top of the list. After the conversion has been
completed, the chart numbers disappear from the
window. Further the color of a chart cell frame
changes to green when conversion of the cell is
completed. The conversion may take 4 - 5 hours,
depending on the quantity of chart numbers
installed.
[Update number is too low]
[No Base Cell available]
Chart cell number
[S57LOAD] window