Furuno CSH-23 SONAR User Manual


 
41
LC fixing position priority
Latitude and Longitude are set to LC with S3 on the DIP switch DP-1.
1. LC-RMA from NMEA
2. LC-RMA from CI/NMEA
3. <24> from CIF port
Depth priority
Depth is set to CIF/NMEA with S5 on the DIP switch DP-1.
1. SD-DPT from NMEA port
2. SD-DPT from CI/NMEA port
3. SD-DBT from NMEA port
4. SD-DBT from CI/NMEA port
5. <57> from CIF port
Ship’s movement data priority (data from GPS/DR)
Ship’s movement data is set to GPS·DR with S1/S2 on the DIP switch DP-1
1. GP-VTC from NMEA port
2. GP-VTC from CI/NMEA port
3. GP-RMC from NMEA port
4. GP-RMC from CI/NMEA port
5. <48> from CIF port
6. <41> from CIF port
Ship’s movement data priority (data from Current indicator)
Ship’s movement data is set to Current indicator with S1/S2 on the DIP switch DP-1
1. VD-VTG from NMEA port
2. VD-VTG from CI/NMEA port
3. VD-VHW from NMEA port
4. VD-VHW from CI/NMEA port
5. CIF signal <66> from CI/NMEA port
6. <66> from CIF port
Ship’s movement data priority (data from Gyro/Navigation)
Ship’s movement data is set to Gyrocompass/navigation with S1/S2 on the DIP switch
DP-1.
1. GP-VTG from NMEA port
2. GP-VTG from CI/NMEA port
3. GP-RMC from NMEA port
4. GP-RMC from CI/NMEA port
5. LC-VTG NMEA port
6. LC-VTG from CI/NMEA port
7. LC-RMA from NMEA port
8. LC-RMA from CI/NMEA port
9. <48> from CIF port
10. <44> from CIF port
Current data (Multi layer) priority
1. VD-CUR from NMEA port
2. VD-CUR from CI/NMEA port
3. CIF signal <76> from CI/NMEA port
4. <76> from CIF port
Current data (single layer) priority
1. VD-VDR from NMEA port
2. VD-VDR from CI/NMEA port
3. CIF signal <56> from CI/NMEA port
4. <56> from CIF port