Furuno FAR-2167DS Marine RADAR User Manual


 
2-5
13.In the order shown in the figure below, pass the gland nut, flat washers (3 pcs.) and gasket
onto the HV cable.
14.As shown in the figure below, fold back the armor onto the flat washer and insert it thru the
other flat washer. Cut off the part of the armor that protrudes past the washer.
15.Pass the HV cable through its cable gland and tighten gland nut.
16.Using the terminal opener, connect wiring to TB901, referring to the interconnection diagram.
17.Close the cover.
18.Seal the cable gland for the HV cable with putty.
Fabricating the power cable TYPCY-2.5
1. Use a ratchet or box wrench to open the port-side cover on the antenna unit.
2. Unfasten the gland nut for the power cable and remove gasket, flat washer (3 pcs.) and gland
cap. (The gland cap may be discarded.)
3. Fabricate the power cable as shown below. Unravel the armor. Wrap sheath with vinyl tape to
fix base of vinyl wire.
How to fabricate power cable TYPCY-2.5
(1)
Flat washer
(2) (3)
Cut off armor that
protrudes past washer.
Gasket
HV cable
Gland nut
High voltage is present at the No. 6 pin
of TB901. Miswiring at this pin can
damage the antenna unit.
CAUTION
25 mm
5 mm
FV2-4
Sheath
Armor
Vinyl sheath
Conductor
S = 2.50 mm
2
φ = 2.01 mm
Armor
Sheath
SECTIONAL VIEW
230 mm