Furuno FSV-30S SONAR User Manual


 
2-16
2.5.2 Raise/Lower control box
Connect the power cable (3φ) and the transceiver unit cable (10S2078) as shown below.
TB-C101
Connect the power cable TPYCY-4
(Japan Industrial Standard) or the
equivalent cable to this terminal board.
LED (Red)
For detection of phase reversal on
3 phase power cable
CN-C101
Connect the transceiver
cable (10S2078) here.
Conductor
S = 4 mm
2
= 2.55 mm
Vinyl
sheath
Armor
Cable TPYCY-4
Sheath
Confirm LED after completing the installation. The LED lights (in red) if power connection is
correct. If it is off, turn off power from the mains switchboard, check the cable connection
and recheck the LED. The hull unit does not work if this connection is wrong.
Normal phase: LED lights (in red).
Phase reversal: LED does not light.
Power cable (3φ)
TPYCY-4
Cable from
transceiver unit
10S2078
Raise/lower control box, cover removed