Furuno GD-1920C-BB Marine RADAR User Manual


 
7. CUSTOMIZING YOUR UNIT
7-18
CHART CONFIGURATION menu description (con’t from previous page)
Object Content Setting Description
LOCK Keeps current chart scale. CHART LEVEL Maintains current chart scale
regardless of zoom setting
UNLOCK Chart scale may chosen freely.
PLOTTER/
OVERLAY
Value-added data shown on plotter
and overlay displays.
PLOTTER Value-added data shown on plotter
display.
VALUE-
ADDED DATA
Show/hide the "Conservation
Area" for *Australian waters.
(*Contact Australian authorities
for details.)
OFF Value-added data is disabled.
PLOTTER/
OVERLAY
Camera icon shown on plotter and
overlay displays.
PLOTTER Camera icon shown on plotter
display.
CAMERA ICON Show/hide camera icon, which is
used to display an image from
icon location. To display an
image, choose camera icon
(
), push the ENTER knob and
then press the IMAGE soft key.
OFF Camera icon is disabled.
*
1
SAFETY STATUS INDICATION
The following indications are shown beneath the range indication to denote safety
status:
NORMAL BEST MAP DATA OFF DE-CLUTTER DANGER
NORMAL (or U.ZOOM or O.ZOOM):
This indication appears to help you select a suitable chart scale.
NORMAL: Suitable chart scale is selected.
U.ZOOM: Chart scale is too small.
O.ZOOM: Chart scale is too large.
BEST MAP: Shown in red when the unsuitable chart scale is selected.
DATA OFF: Mixing levels can be turned on when the electronics chart coverage area
does not provide enough coverage to completely fill the display screen. When the
cursor or own ship mark is placed in the area with coverage, the chart data is shown as
below.
On: The chart line in the area with no coverage is shown. This area is filled with dots.
Off: The area with no coverage is not shown (goes to white).
DECLUT.: For C-MAP MAX charts, symbols of low priority (ex. map symbols on land)
can be automatically hidden to unclutter the screen when you change the scale. When
the function is turned on, DECLUT. appears in red.
DANGERS: Shown in red when the GROUNDING alarm detects the high-risk object
(listed in the grounding report) when the GROUNDING alarm is turned on.
CAUTIONS: Shown in red when the GROUNDING alarm detects the low-risk object
when the GROUNDING alarm is turned on.