4
2. WIRING
All wiring are terminated at the rear of the display unit.
Antenna unit
GPA-017
(GP-1650W)
Earth terminal
DGPS beacon receiver
(option for GP-1650W,
RS-232C only)
External
equipment
Black
White
Shield
Displa unit
GPA-019
(GP-1650WD)
ANT
XDR
DGPS
NMEA
13GND
2
12-24
VDC
-
+
Display unit, rear view
Power cable
Connect the power cable to the power connector. Connect the leads to the battery (12 or 24
VDC); white to plus(+) terminal and black to minus(-) terminal.
Cable connector
Power cable
w/fuse (3A)
Lead wire
White
Black
BATTERY
Connecting the power cable to the battery