Furuno GP-1850W Marine GPS System User Manual


 
1. INSTALLATION
3
Flush mounting
Note: Use supplied pan head screws when the thickness of the bulkhead is from 11 to 14
mm. For bulkhead which exceeds 14 mm in thickness the length of the pan head
screws should be bulkhead thickness plus 7.3±1.5 mm. Also the length of B should
max. 7mm.
BA
1. Prepare a cutout in the mounting location whose dimensions are as shown on the next
page.
2. Fix the display unit by six pan head screws M4 X 20. Refer to the outline drawing on
page D-2.
Flush mount
Pan head screws
(Cutout for flush mount)
147 0.5
89 0.5
143 1
4.5
50
244 1
15 0.5
238 1
242 0.5
6-R2.25
Flush mounting of display unit