Installation
4 313293C
Installation
It is required to remove the power supply before install-
ing the alternator conversion kit. Always have a qualified
electrician perform wiring connections.
Remove Power Supply
1. Shutdown XM plural-component sprayer. See oper-
ation manual 312359 for shutdown procedure.
2. Disconnect incoming power cable connections to
power supply (E) and ground lead (X) from junction
box (JB).
3. Disconnect power supply cable (G) from fluid control
module (D).
4. Disconnect power cable from power filter (F) and
from terminal blocks in junction box (not shown).
5. Loosen mounting screws and remove power supply
(E) and filter (F) from control box (CB).
6. Disconnect CAN cable (H) from USB front CAN con-
nector and display module (C). See F
IG. 1 on page
3.
NOTE:
Cable (H) will not be used for alternator conversion kit.
7. Disconnect CAN cable (J) from USB module and
fluid control module. Do not discard cable (J). CAN
cable (J) will be used by alternator conversion kit.
NOTE:
Keep power supply (E) and filter (F) connected so that
you can easily reinstall your power supply.
FIG. 2: Remove Power Supply
E
F
G
JB
X
D
r_256991_313293_3