Graco 334014A Marine Sanitation System User Manual


 
Technical Data
Technical Data
US
Metric
Maximum fluid working pressure
200 psi 1.4 MPa,14.0 b
ar
Air pressure o
perating range
20-100 psi 0.14-0.69 MPa
, 1.4-6.9 bar
Fluid displa
cement per cycle
Low Pressure Setting
0.17 g 0.64 l
High Pressure Setting
0.20 g 0.76 l
Air consumpt
ion
at 70 psi, 20 gpm at 4.8 bar, 76 lpm
Low Pressure Setting 26 scfm
0.7 cubic me
ters per minute
High Pressure Setting 51 scfm
1.4 cubic me
ters per minute
Maximum val
ues with water as media under submerged inlet conditions at ambient temperature:
Maximum ai
rconsumption
Low Pressure Setting 59 scfm
1.7 cubic m
eters per minute
High Pressure Setting 95 scfm
2.7 cubic m
eters per minute
Maximum free-flow delivery
Low Pressure Setting
50 gpm 189 lpm
High Pressure Setting
46 gpm 174 lpm
Maximum p
ump speed
Low Pressure Setting
280 cpm
High Pressure Setting
225 cpm
Maximum suction lift (varies widely
based on ball/seat selection and
wear, operating speed, material
properties, and other variables)
16 ft dry,
29 ft wet
4.9 m dry
8.8 m wet
Maximum size pumpable solids 1/8 in 3.2 mm
Recommended cycle rate for continuous
use
93–140 cpm
(in Low or High pressure setting)
Recom
mended cycle rate for circulation
syst
ems
20 cpm
(in Low or High pressure setting)
Air i
nlet size
3/4 npt(f)
Flui
d inlet size
1 in. npt(f) or 1 in. bspt
Flui
d outlet size
1 in. npt(f) or 1 in. bspt
Wei
ght
48 lb (aluminum manifolds)
60 lb (SST manifolds)
21.8 kg (aluminum manifolds)
27.2 kg (SST manifolds)
20 334014A