HP (Hewlett-Packard) 5345AOPT12 Fish Finder User Manual


 
TB 9-6625-1996-35
6
9. Sensitivity
a. Performance Check
(1) Set function generator as listed in (a) through (c) below:
(a) Output Type to UnBalanced 600
(b) Function to Sine Wave.
(b) Frequency to 10 Hz.
(c) Amplitude to 1 mV.
(2) Position TI controls as listed in (a) through (f) below:
(a) CHANNEL A LEVEL control to PRESET.
(b) CHANNEL A SLOPE switch to +.
(c) CHANNEL A 50/1M switch to 50.
(d) CHANNEL A ATTEN X1/X10 switch to X1.
(e) CHANNEL A AC/DC switch to DC.
(f) CHECK/COM A/SEP switch to SEP.
(3) Connect TI CHANNEL A input to function generator Function Output
Unbalanced.
(4) Press the function generator Enter key to enable the knob, and slowly rotate
the function generator knob cw until TI display GATE light flashes and indication is
stable at approximately 10 Hz.
(5) Verify that the function generator indicates within limits specified in table 3.
If not perform b below.
(6) Repeat technique of 1 through (5) above for remaining settings listed in table
3.
Table 3. Sensitivity
Test
instrument
input
CHECK-COM
A-SEP switch
setting
Function generator/signal
generator frequency
setting
Function generator/signal
generator indications
()
CHANNEL A SEP 10 Hz 0.071 VPP
CHANNEL A SEP 10 kHz 0.071 VPP
CHANNEL A SEP 100 kHz 0.071 VPP
CHANNEL A SEP 1 MHz 0.071 VPP
CHANNEL A
1
SEP 10 MHz 0.025 VRMS
CHANNEL A SEP 100 MHz 0.025 VRMS
CHANNEL A SEP 500 MHz 0.025 VRMS
CHANNEL A
2
COM A 10 Hz 0.141 VPP
CHANNEL A COM A 10 kHz 0.141 VPP
CHANNEL A COM A 100 kHz 0.141 VPP
CHANNEL A COM A 1 MHz 0.141 VPP
CHANNEL A
1
COM A 10 MHz 0.050 VRMS
CHANNEL A COM A 100 MHz 0.050 VRMS
CHANNEL A COM A 400 MHz 0.050 VRMS
1
Substitute the signal generator for the function generator.
Substitute the function generator for the signal generator.
2