5 - 1
SECTION 5 ADJUSTMENT PROCEDURES
5-1 PREPARATION
Enter the adjustment mode when adjusting the IC-2200H Then the JIG cable as shown the page 5-2 is required .
■ REQUIRED TEST EQUIPMENT
DC power supply
RF power meter
(terminated type)
Frequency counter
Standard signal
generator (SSG)
FM deviation meter
Oscilloscope
Audio generator
Attenuator
EQUIPMENT GREDE AND RANGE EQUIPMENT GREDE AND RENGE
Output voltage : 13.8 V DC
Current capacity : 20 A or more
Measuring range : 0.1–100 W
Frequency range : 50–400 MHz
Impedance : 50 Ω
SWR : Less than 1.2 : 1
Frequency range : 0.1–400 MHz
Frequency accuracy : ±1 ppm or better
Sensitivity : 100 mV or better
Frequency range : 0.1–400 MHz
Output level : 0.1 µV–32 mV
(–127 to –17 dBm)
Frequency range : 0–400 MHz
Measuring range : 0 to ±5 kHz
Frequency range : DC–400 MHz
Measuring range : 0.01–10 V
Frequency range : 300–3000 Hz
Measuring range : 1–500 mV
Power attenuation : 50 or 60 dB
Capacity : 150 W or more
■ ENTERING THE ADJUSTMENT MODE
q Turn the transceiver’s power OFF.
w Connect the JIG cable to the [MIC] jack.
e Push and hold the [SET] and [MONI] keys, and then turn power ON.
NOTE: Exiting from the adjustment mode when the transciever’s power is OFF.
■ OPERATING ON THE ADJUSTMENT MODE
• Change the adjustment value : [DIAL]
• Verifying the adjustment value : [M/CALL] key
• Forward the adjustment item : [BANK] key
• Go back the adjustment item : [V/MHz] key
• Store the adjustment value in the memory : [S.MW] key
CAUTION: Need to push the [S.MW] key when storing the adjustment value in the memory. Otherwise, the transceiver is not
adjusted properly.
IMPORTANT!: The transceiver need to be cancelled adjustment mode (as following method) to use normal mode when
adjustments are finished, otherwise the transceiver does not work properly.
q: Turn the power OFF.
w: Push and hold [S.MW] and [SET] keys, and then turn the power ON.