5 - 4
SOFTWARE ADJUSTMENTS (TRANSMITTING AND RECEIVING)–Continued
DIGITAL
REFERENCE
DEVIATION
[dt+DIGITAL]
RECEIVER
SENSITIVITY
[tr]
SQUELCH
LEVEL
(Wide)
[Sq]
S-METER
(FM mode)
[Sr]
(AM mode)
[Sr+.]
1
1
2
3
4
1
1
2
• Operating frequency : 146.0 MHz
• IF bandwidth : Wide
• No audio signal is applied to the [MIC] jack.
• Connect an FM deviation meter to the antenna con-
nector and set as :
HPF : OFF
LPF : 20 kHz
De-emphasis : OFF
Detector : (P–P)/2
• Transmitting
• Operating frequency : 118.020 MHz
• Connect an SSG to the antenna connector and set as
Level : 0.5 µV* (–113 dBm)
Modulation : 1 kHz
Deviation : ± 3.5 kHz
• Receiving
• Operating frequency : 136.020 MHz
• Receiving
• Operating frequency : 147.980 MHz
• Receiving
• Operating frequency : 173.980 MHz
• Receiving
• Operating frequency : 145.020 MHz
• Connect an SSG to the antenna connector and set as
Level : 0.1 µV* (–127 dBm)
Modulation : 1 kHz
Deviation : ± 3.5 kHz
• Receiving
• Operating frequency : 145.020 MHz
• Connect an SSG to the antenna connector and set as
Level : 1.3 µV* (–105 dBm)
Modulation : 1 kHz
Deviation : ± 3.5 kHz
• Receiving
• Operating frequency : 127.020 MHz
• Connect an SSG to the antenna connector and set as
Level : 1.0 µV* (–107 dBm)
Modulation : 1 kHz
Deviation : 30 %
• Receiving
• Turn the [DIAL] to set to ±0.85 kHz.
• Push the [S.MW] key after finish adjustment.
• Push the [S.MW] key.
• Push the [S.MW] key.
• Push the [S.MW] key.
• Push the [S.MW] key.
• Turn the [DIAL] to set to squelch tight point.
• Turn the [DIAL] to set to squelch threshold point.
• Push the [S.MW] key.
• Push the [S.MW] key.
• Push the [S.MW] key.
ADJUSTMENT ADJUSTMENT CONDITION OPERATION
*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.