La Crosse Technology WS-6020U-IT Marine Instruments User Manual


 
6
It checks the brightness level of the
surrounding environment every 5 seconds.
It measures / transmits every 16 seconds if it
detects a dark environment or if the battery
voltage drops below 2.5V.
(2) IDLE MODE:
If the battery voltage drops below 2.4V, it
commences IDLE MODE; the LCD turns off
and it does not measure / transmit weather
data.
It checks the brightness level of the
surrounding environment every 5 seconds.
If battery voltage rises back to 2.5V or
above, it returns to NORMAL MODE.
If the environment remains dark for 72 hours,
it commences STOP MODE.
(3) STOP MODE (STANDBY):
Occurs when the environment remains dark
for 72 hours OR if you manually commence
STOP MODE (standby) by covering the solar
cell for 10 seconds and then press the
RESET key one time.
NOTE: The LCD will display "StP" then turn
off and commence STOP MODE.
While in STOP MODE (standby), the LCD is
off and the Sensor does not perform any
normal operations.
To resume normal operation, ensure the
Sensor is in a bright environment (next to a